[Operation Tutorial] Calibration Method of Topcon LZ-T5 Laser Transmitter

[Operation Tutorial] Calibration Method of Topcon LZ-T5 Laser Transmitter

August 22, 2024

LZ-T5

Method for calibrating laser transmitter

Based onv15 New editionP3DSoftware(The method is the same for older software,The display interface has changed slightly)

One、 Preparations 

01 Instrument preparation :

Reference Station&Mobile Station*1

Tripod*3

Base*3

Handbooks

PZS-1 Receiver

LZ-T5 Transmitter

 

02 Erection of base station :

For example, the new project has not undergone coordinate conversion.,Customizable coordinate system for temporary coordinate conversion,This is the most common method。(If there is a coordinate transformation, the base station can be started by using a known point.)

1

After the project is created,Enter the hand bookP3DSoftware  Data ⇒Control⇒ Add to  Menu,Enter custom control point information,A single point is enough。

Figure 1

2

Set up the base station(Centering and leveling may not be performed.,If there is no tripod, it can be placed directly in the open position.),Start the base station with the known point just added。

3

Back to  Data ⇒Control Menu, Editor  Figure 1Control point as shown,Check the bottom horizontal and vertical coordinate conversion and confirm。

 

03 LZ-T5 Placement and erection of transmitter and mobile station:

1

Try to choose flat ground.,Avoid excessive height difference。

2

Set up a tripod to place the base and level it,PlaceLZ-T5,Measuring Transmitter Coordinates Using a Rover。

3

Loft emitter coordinate points,A second tripod is erected at a distance of about 30 meters.,Use the base to transfer the rover station andPZS-1 Fixed on a tripod。

 

 

 

 

 

Two、 Open  LZ-T5 Calibration mode for

Press on  Laser verticality mode keyIn the meantime,Click Power key,Lasts two seconds.,Calibration mode can be entered,At this timeChannel light by 1-4 Flashing in turn

Figure 2

Three、 Perform the calibration 

01 Add transmitter information 

Get into Control⇒mmGPSTransmitterInterface 

ClickNew… Add an emitter 

Figure 3

 

Serial number:Enter the transmitterS/N(ExampleLR1835) 

Type:LZ-T5 

Passageway:CH1~CH4 Select according to the actual situation 

Control Point:Lecting laser erection position coordinate point 

Elevation:Measuring laser oblique height 

Press “Confirm” Preservation 

Figure 4

Click“ Download ”Enter the Bluetooth search interface,Select the transmitter after refreshing BluetoothS/NMake a Bluetooth connection and download the transmitter data 。

Figure 5

Such as:LZ-T5 LR1835 

 

 

When the download is complete,The firmware version number of the transmitter is displayed(There are two versions of the transmitter 1.21 and 2.00) 

Figure 6

 

02 Start calibration 

After selecting the corresponding laser transmitter,ClickCalibration… 

Figure 7

 

Calibration warning content: 

1) Transmitter is in calibration mode 

2) Transmitter and receiver in the same horizontal position(Height difference 1°Within) 

3) The distance between them is about 30 meters. 

Figure 8

 

Click after meeting the above content“Next step”Perform the calibration 

 

First letLZ-T5 Transmitter front(One side with keys)Toward the rover,After waiting for automatic leveling,Click Next,Complete the front calibration 。

Figure 9

If the transmitter and receiver are not in the same horizontal position,When observing in this step, it will indicate too high or too low.,At this time, adjust the height of the receiver accordingly. 。

Figure 10

Follow the promptsCounter clockwiseRotate each face of the alignment laser emitter。Calibrate the four faces in turn 。

Figure 11

Note:Please turn the upper part of the base,Do not turn the transmitter itself 

The calibration results appear after the four faces have been calibrated,Software default is greater than or equal to±5″It needs to be adjusted,Otherwise, no adjustment is required.。 

Figure 12

If adjustment is required: 

After clicking Finish, the connection interface will pop up.,Will hand thin andLZ-T5 Laser transmitter connection to update calibration data。 

Figure 13

When the update is complete, the date of the update is displayed,LZ-T5 will automatically shut down。 

Contribution:Intelligent Construction Business Department MJH

Featured

XCMG: Six bridges and two engines, XCA400L8 _ 1 is high-tech!

XCMG: Six bridges and two engines, XCA400L8 _ 1 is high-tech!

Set a New National Record, Sinotruk Heavy Truck Export Exceeds 14000 Vehicles in February!

Set a New National Record, Sinotruk Heavy Truck Export Exceeds 14000 Vehicles in February!

Renovation of Patterns? Zhonglian Mining Machine "Customer Activity Day" Officially Opened

Renovation of Patterns? Zhonglian Mining Machine "Customer Activity Day" Officially Opened

Good news of delivery | Batch delivery of 30 SJM 3090F wide-body dump trucks

Good news of delivery | Batch delivery of 30 SJM 3090F wide-body dump trucks

Trending Products

XCMG Official 5m 1000W*2 Hand Push Operated Lifting Telescopic Mobile Metal Halide Lamp Balloon Light Tower

XCMG Official 5m 1000W*2 Hand Push Operated Lifting Telescopic Mobile Metal Halide Lamp Balloon Light Tower

XCMG Official 5m Hand Push Lifting Telescopic Mobile Halogen Lamp Light Tower for Construction Site and Mining

XCMG Official 5m Hand Push Lifting Telescopic Mobile Halogen Lamp Light Tower for Construction Site and Mining

XCMG Factory 9m Hydraulic Mast Diesel Generator Trailer Mobile LED Stadium Light Tower